Fortron FSP EP 2000
Model
EP 2000
Capacity
2000 VA / 1200W
Input/ Voltage
110/120 VAC or 220/230/240 VAC
Input/ Voltage Range
81-145 VAC / 162-290 VAC
Input/ Frequence
60/50 Hz (auto sensing)
Output/ Voltage
±10%
Output/ Frequence Range
60 Hz or 50 Hz ±1 Hz
Output/ Transfer Time(Typical)
Typical 2-6 ms, 10ms max
Output/ Waveform(Batt. Mode)
Simulated Sine Wave
Battery/ Battery Type & Number
12 V/ 9 AH x 2
Battery/ Backup Time(One PC load@120W)
30 min.
Battery/ Typical Recharge Time
4-6 hours recover to 90% capacity
Indicators/ Ac Mode
The right green LED lighting & the 2nd to 5th green LEDs gradually lighting indicating load level
Indicators/ Battery Mode
The right green LED flashing & the 2nd to 5th green gradually lighting indicating battery capacity
Indicators/ Fault
Red lighting
Protection/ Full Protection
Overload, discharge, and overcharge protection
Alarm/ Battery Mode
Sounding every 10 seconds
Alarm/ Low Battery
Sounding every second
Alarm/ Overload
Sounding every 0.5 second
Alarm/ Battery Replacement Alarm
Sounding every 2 seconds
Alarm/ Fault
Continuously sounding
Physical/ Output Receptacles
Schuko x 3 + IEC x 3/ also provide India, French, Schuko, NEMA, and IEC for selections
Physical/ Dimension, D x W x H (mm)
397 x 146 x 205
Physical/ Net Weight (kgs)
11.5
Operating Environment/ Humidity
0-90 % RH @ 0- 40°C (non-condensing)
Operating Environment/ Noise Level
Less than 40dB
Management/ Optional USB/ RS-232 Port
Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC8